Communicators

are winners!

News

13.03.2018
Fission Hits Three New High-Grade Holes at R1515W

Fission Hits Three New High-Grade Holes at R1515W

 

Step-out drilling continues to expand Triple R’s westernmost zone

 

FISSION URANIUM CORP. ("Fission" or “the Company" - https://www.youtube.com/watch?v=AudsaLrYPgM&t=18s) is pleased to announce results from its final four Winter drill holes on the R1515W zone, at its’ PLS property, in Canada's Athabasca Basin region. All four holes have hit mineralization, with three intercepting high-grade radioactivity. The shallow depth, R1515W is the westernmost zone of the Triple R deposit and these latest results have expanded mineralization on lines 1560W, 1530W and 1500W. The holes include PLS18-574 (line 1560W), which intersected 42.0m of total composite mineralization, including 5.60m of total composite radioactivity >10,000 cps (with a peak of >65,535 cps).

                           

Drilling Highlights

-          R1515W zone expanded on lines 1560W, 1530W and 1500W

 

-          Hole PLS18-574 (line 1560W)

  • 42.0m total composite mineralization over a 119.0m interval (between 128.0m – 247.0m), including
  • 5.60m of total composite >10,000 cps

 

-          Hole PLS18-577 (line 1530W)

  • 47.5m total composite mineralization over a 181.5m interval (between 127.0m – 308.5m), including
  • 0.70m of total composite >10,000 cps

 

 

Ross McElroy, President, COO, and Chief Geologist for Fission, commented,

 

"All 8 holes that we’ve drilled on the R1515W zone this winter has hit mineralization and we’ve continued to see very encouraging results. This most recent batch of drill holes includes wide, high-grade mineralization and an expansion of the zone, both laterally and at depth on lines 1560W, 1530W and 1500W. The R1515W remains open and prospective for future drill programs.

 

Table 1:  R1515W Zone

Hole ID

Zone

Grid Line

Collar

Hand-held Scintillometer Results On Mineralized Drillcore (>300 cps / >0.5M minimum)

Lake
Depth
(m)

Sandstone
From - To
(m)

Basement Unconformity
Depth
(m)

Total Drillhole
Depth
(m)

Az

Dip

From (m)

To (m)

Width (m)

CPS Peak Range

PLS18-574

R1515W

1560W

343

-79.0

128.0

128.5

0.5

380

NA

NA

102.0

350.0

 

 

 

 

 

138.0

138.5

0.5

660

 

 

 

 

 

 

 

 

 

154.0

155.0

1.0

470 - 650

 

 

 

 

 

 

 

 

 

159.0

171.0

12.0

<300 - 800

 

 

 

 

 

 

 

 

 

184.0

185.5

1.5

300 - 700

 

 

 

 

 

 

 

 

 

188.0

202.5

14.5

310 - >65,535

 

 

 

 

 

 

 

 

 

212.5

222.0

9.5

<300 - >65,535

 

 

 

 

 

 

 

 

 

224.5

226.5

2.0

410 - 3100

 

 

 

 

 

 

 

 

 

246.5

247.0

0.5

520

 

 

 

 

PLS18-576

R1515W

1560W

325

-79.3

162.0

163.0

1.0

320 - 1000

NA

NA

105.4

338.0

 

 

 

 

 

184.5

188.5

4.0

390 - 6200

 

 

 

 

PLS18-577

R1515W

1530W

321

-84.6

127.0

127.5

0.5

480

NA

NA

101.1

416.0

 

 

 

 

 

136.5

137.0

0.5

410

 

 

 

 

 

 

 

 

 

153.5

155.5

2.0

<300 - 850

 

 

 

 

 

 

 

 

 

158.0

175.5

17.5

<300 - 14500

 

 

 

 

 

 

 

 

 

178.5

179.5

1.0

350 - 950

 

 

 

 

 

 

 

 

 

183.0

183.5

0.5

2800

 

 

 

 

 

 

 

 

 

204.5

207.5

3.0

<300 - 350

 

 

 

 

 

 

 

 

 

216.5

217.5

1.0

350 - 400

 

 

 

 

 

 

 

 

 

232.0

234.0

2.0

1400 - 6000

 

 

 

 

 

 

 

 

 

243.0

247.0

4.0

<300 - 3000

 

 

 

 

 

 

 

 

 

258.5

261.5

3.0

380 - 1400

 

 

 

 

 

 

 

 

 

265.5

268.5

3.0

<300 - 970

 

 

 

 

 

 

 

 

 

271.0

278.5

7.5

360 - 10500

 

 

 

 

 

 

 

 

 

294.5

295.0

0.5

360

 

 

 

 

 

 

 

 

 

307.0

308.5

1.5

540 - 640

 

 

 

 

PLS18-578A

R1515W

1500W

324

-80.9

149.0

155.0

6.0

<300 - 2800

NA

NA

108.4

305.0

 

 

 

 

 

162.5

174.0

11.5

<300 - 26500

 

 

 

 

 

 

 

 

 

195.0

195.5

0.5

1300

 

 

 

 

 

 

 

 

 

208.0

208.5

0.5

2700

 

 

 

 

 

 

 

 

 

212.0

212.5

0.5

350

 

 

 

 

 

 

Natural gamma radiation in drill core that is reported in this news release was measured in counts per second (cps) using a hand held RS-121 Scintillometer manufactured by Radiation Solutions, which is capable of discriminating readings up to 65,535 cps. Natural gamma radiation in the drill hole survey that is reported in this news release was measured in counts per second (cps) using a Mount Sopris 2GHF-1000 Triple Gamma probe, which allows for more accurate measurements in high grade mineralized zones.  The Triple Gamma probe is preferred in zones of high grade mineralization.  The reader is cautioned that scintillometer readings are not directly or uniformly related to uranium grades of the rock sample measured, and should be used only as a preliminary indication of the presence of radioactive materials. The degree of radioactivity within the mineralized intervals is highly variable and associated with visible pitchblende mineralization. All intersections are down-hole.  All depths reported of core interval measurements including radioactivity and mineralization intervals widths are not always representative of true thickness.  The orientation of the mineralized intervals tend to follow that of lithologic contacts, and generally dip steeply to the south. Within the Triple R deposit, individual zone wireframe models constructed from assay data and used in the resource estimate indicate that all 5 zones have a complex geometry controlled by and parallel to steeply south-dipping lithological boundaries as well as a preferential sub-horizontal orientation. 

 

 

PLS Mineralized Trend & Triple R Deposit Summary

 

Uranium mineralization of the Triple R deposit at PLS occurs within the Patterson Lake Conductive Corridor and has been traced by core drilling over ~3.18km of east-west strike length in five separated mineralized "zones" which collectively make up the Triple R deposit. From west to east, these zones are: R1515W, R840W, R00E, R780E and R1620E. Through successful exploration programs completed to date, Triple R has evolved into a large, near surface, basement hosted, structurally controlled high-grade uranium deposit.  The discovery hole was announced on November 05, 2012 with drill hole PLS12-022, from what is now referred to as the R00E zone. 

 

The R1515W, R840W and R00E zones make up the western region of the Triple R deposit and are located on land, where overburden thickness is generally between 55m to 100m.  R1515W is the western-most of the zones and is drill defined to ~90m in strike-length, ~68m across strike and ~220m vertical and where mineralization remains open in several directions.  R840W is located ~515m to the east along strike of R1515W and has a drill defined strike length of ~430m.  R00E is located ~485m to the east along strike of R840W and is drill defined to ~115m in strike length.  The R780E zone and R1620E zones make up the eastern region of the Triple R deposit.  Both zones are located beneath Patterson Lake where water depth is generally less than six metres and overburden thickness is generally about 50m.  R780E is located ~225m to the east of R00E and has a drill defined strike length of ~945m.  R1620E is located ~210m along strike to the east of R780E, and is drill defined to ~185m in strike length.

 

Mineralization along the Patterson Lake Corridor trend remains prospective along strike in both the western and eastern directions. Basement rocks within the mineralized trend are identified primarily as mafic volcanic rocks with varying degrees of alteration.  Mineralization is both located within and associated with mafic volcanic intrusives with varying degrees of silicification, metasomatic mineral assemblages and hydrothermal graphite. The graphitic sequences are associated with the PL-3B basement Electro-Magnetic (EM) conductor.

 

Patterson Lake South Property

 

The 31,039 hectare PLS project is 100% owned and operated by Fission Uranium Corp. PLS is accessible by road with primary access from all-weather Highway 955, which runs north to the former Cluff Lake mine and passes through the nearby UEX-Areva Shea Creek discoveries located 50km to the north, currently under active exploration and development.

 

The technical information in this news release has been prepared in accordance with the Canadian regulatory requirements set out in National Instrument 43-101 and reviewed on behalf of the company by Ross McElroy, P.Geol., President and COO for Fission Uranium Corp., a qualified person.

 

About Fission Uranium Corp.

 

Fission Uranium Corp. is a Canadian based resource company specializing in the strategic exploration and development of the Patterson Lake South uranium property - host to the class-leading Triple R uranium deposit - and is headquartered in Kelowna, British Columbia.  Fission’s common shares are listed on the TSX Exchange under the symbol "FCU" and trade on the OTCQX marketplace in the U.S. under the symbol "FCUUF."

 

 

ON BEHALF OF THE BOARD

 

"Ross McElroy"

                         

Ross McElroy, President and COO

 

Investor Relations

Rich Matthews

TF: 877-868-8140

rich@fissionuranium.com

www.fissionuranium.com

 

In Europe:

Swiss Resource Capital AG

Jochen Staiger

info@resource-capital.ch

www.resource-capital.ch

 

Fission Uranium Corp.

Suite 700 – 1620 Dickson Ave.

Kelowna, BC  V1Y 9Y2

 

TSX SYMBOL: FCU

OTCQX SYMBOL: FCUUF   

FRANKFURT SYMBOL: 2FU

 

 

Cautionary Statement:

 

Certain information contained in this press release constitutes “forward-looking information", within the meaning of Canadian legislation. Generally, these forward-looking statements can be identified by the use of forward-looking terminology such as "plans", "expects" or "does not expect", "is expected", "budget", "scheduled", "estimates", “forecasts", "intends", "anticipates" or "does not anticipate", or "believes", or variations of such words and phrases or state that certain actions, events or results "may", "could", "would", "might" or "will be taken", "occur", "be achieved" or “has the potential to”.  Forward looking statements contained in this press release may include statements regarding the future operating or financial performance of Fission and Fission Uranium which involve known and unknown risks and uncertainties which may not prove to be accurate. Actual results and outcomes may differ materially from what is expressed or forecasted in these forward-looking statements. Such statements are qualified in their entirety by the inherent risks and uncertainties surrounding future expectations. Among those factors which could cause actual results to differ materially are the following: market conditions and other risk factors listed from time to time in our reports filed with Canadian securities regulators on SEDAR at www.sedar.com. The forward-looking statements included in this press release are made as of the date of this press release and the Company and Fission Uranium disclaim any intention or obligation to update or revise any forward-looking statements, whether as a result of new information, future events or otherwise, except as expressly required by applicable securities legislation.

 

 



NEWSLETTER REGISTRIERUNG:



Aktuelle Pressemeldungen dieses Unternehmens direkt in Ihr Postfach:
Newsletter...

Mitteilung übermittelt durch IRW-Press.com. Für den Inhalt ist der Aussender verantwortlich.

Kostenloser Abdruck mit Quellenangabe erlaubt.